Basic Info.
Certification
API, ISO, CB, CE
Application
Collector Controller, Solar System Controller, Charger Controller, Solar Working Station, Voltage Controller
Working Temperature
-25-55
Transport Package
Paper Box
Specification
19.6*10.5*5.9
Product Description
The product is multi-functional LCD solar controller with clock display and seven operating modes that are charging mode, light control mode, light and time delay control mode, universal control mode, manual control mode, timing control mode and testing mode. Among them, test mode is only applicable to the factory test. Charging control is applicable to any mode, as long as the charging condition is reached, it can charg immediately. Discharge control varies as different control modes change, undert the trouble-free condition.
(5) Mode controlling display area
"Operate Mode Select" keeps on; It means that the area is the alternative area of controlling mode.
"Charging" keeps on, it means that the controller is in charging mode.
"Light Control" keeps on, it means that the controller is in light control mode.
"Light Control and delay" keeps on, it means that the controller is in light start and time delay stop control mode.
"Universal Control" keeps on, it means that the controller is in universal control mode.
"Manual" keeps on, it means that the controller is in manual control mode.
"Timing" keeps on, it means that the controller is in timing control mode.
"Test" keeps on, it means that the controller is in test mode.
(6) Normal and fault display area
"OK" keeps on, it means that the controller is in normal state.
"Fault" flickers, it means that the controller detects the abnormalities of battery's voltage, discharge current or controller's temperature. When the battery's voltage is abnormal, "Fault" flickers, in the meantime, the value of voltage also flickers. When the discharge current is too large, "Fault" flickers, meanwhile, abnormal current value also flickers. When the controller's temperature exceeds 75ºC, "Fault" flickers, and the value of temperature also flickers.
2. Operating instructions
(1) "" Numerical values and mode adjustment.
"" Setting/confirmation
"" Displacement and impulse start/stop
(2) Time setting
When charged, it immediately enter time setting state, load output and the first one(the first one to the left) of the four values in the parameters display area flicker, it means that this place is changeable, press "" to adjust, press "" for displacement adjustment. If time needs adjusting again, then long press "" for 5 seconds to enter time setting state.
(3) Mode adjustment
Press "", the current control mode can flicker, then press "" to get the needed control mode, then press "" again to confirm.
(4)Delay stop time adjustment of light control +delay stop control mode.
When "Light Control and delay" is chosen and confirmed, it will automatically pop up the delay stop time parameters, the operational approach is the same as time setting operation, load output and the display area of all parameters will show "Time OFF", after adjusting, then press "" to get back to the display mode. If delay stop time parameters needs modifying again, directly press two times of "" to enter delay stop time parameters adjustment.
(5) The adjustment of start time and stop time of timing control mode
When "Timing" control mode is chosen and confirmed, it will automatically pop up time parameters start, the operational approach and time setting are the same, load output and the display area of all parameters will show "Time ON". After adjusting start time and pressing "", it will automatically enter stop time parameters adjustment, load output and the display area of all parameters will show "Time OFF", after finishing adjustment, press ""to get back to display mode.
IV. Protection parameters
(1)Voltage protection instructions
When using 12V battery, if the battery's voltage is below 10.5V, it will delay 6 seconds under low voltage protection, the value of voltage flickers, "Fault" flickers, discharge stops. When voltage gets back to 11.5V, it gets back to normal. When voltage is over 16.0V, the value of voltage flickers, "Fault" flickers, discharge stops. When voltage recovers back to 15.0V, it returns to normal.
When using 24V battery, if the battery's voltage is below 21.0V, it will delay 6 seconds under low voltage protection, the value of voltage flickers, "Fault" flickers, discharge stops. When voltage gets back to 11.5V, it gets back to normal. When voltage is over 16.0V, the value of voltage flickers, "Fault" flickers, discharge stops. When voltage recovers back to 15.0V, it returns to normal.
When using 36V battery, if the battery's voltage is below 31.5V, it will delay 6 seconds under low voltage protection, the value of voltage flickers, "Fault" flickers, discharge stops. When voltage gets back to 34.5V, it gets back to normal. When voltage is over 48.0V, the value of voltage flickers, "Fault" flickers, discharge stops. When voltage recovers back to 45.0V, it returns to normal.
When using 48V battery, if the battery's voltage is below 42.0V, it will delay 6 seconds under low voltage protection, the value of voltage flickers, "Fault" flickers, discharge stops. When voltage gets back to 46.0V, it gets back to normal. When voltage is over 64.0V, the value of voltage flickers, "Fault" flickers, discharge stops. When voltage recovers back to 60.0V, it returns to normal.
(2)Discharge current protection instructions
When discharge current is above 150% of rated current, it starts protection immediately, the value of protection current flickers, "Fault" flickers, discharge stops.
Discharge current is around 110%~150% of rated current, it will delay ten seconds for protection, the value of protection current flickers, "Fault" flickers, discharge stops.
Discharge current is around 100%~110% of rated current, it will delay ten seconds for protection, the value of protection current flickers, "Fault" flickers, discharge stops.
(3)Charging protection instructions
When using 12V battery, if battery's voltage is below 13.0V, it will start to charge, if the voltage is above 14.8V, it will stop charging.
When using 24V battery, if battery's voltage is below 26.0V, it will start to charge, if the voltage is above 29.6V, it will stop charging.
When using 36V battery, if battery's voltage is below 39.0V, it will start to charge, if the voltage is above 44.8V, it will stop charging.
When using 48V battery, if battery's voltage is below 52.0V, it will start to charge, if the voltage is above 59.2V, it will stop charging.
Why Choose Us?
1. We are a professhional manufacturer, specialized in solar home system, solar controller, solar inverter and solar lighting, also accept OEM or ODM.
2. Certificate: We can support CE, RoHS, ISO certificate if you need
3. Life span: At least 10 years life span, and we garantee 2 years
4. Lead Time:
Sample: In three days
Trial small Quantity: We can deliver in 10 days
Mass Quantity: 15-25 days
5. Favourable Payments
We can accept EXW, FOB or CFR, CIF terms, the nearest delivery port is Guangzhou, or shenzhen
We can also print your Logos on the box or products.
Address:
Building A1, Shibei Industrial Park, Panyu District, Guangzhou, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Consumer Electronics, Electrical & Electronics, Lights & Lighting
Management System Certification:
ISO 9000
Company Introduction:
Guangzhou Huami Solar Power Co., Ltd is a high-technical photovoltaic enterprise, which is located in Guangzhou, Guangdong province. And as a bridge connecting the most advanced Chinese photovoltaic industry and the rest of the world.
Our company specializes in solar panel, ranging from 1W to 300W, and solar roof tiles, which is unique in the world, and mainly divided into 8W, 12W, 20W and 24W capacity. All these products get the CE, RoHS, TUV and ISO 9001, ISO14001 certificate. As customer needs, we can supply both off-grid and on-grid solar system. Besides, our solar lamp, solar inverter, solar controller are all very popular in many countries.
Our company is honored with the short lead time, high quality, competitive price and first-class service in the solar power business field, that′s why we can export lots of profucts to Eastern Europe, Northern Europe, Southeast Asia, Africa, andSouth America.
Welcome to visit our company and we are looking forward to cooperating with clients from all over the world!